HHR
FlowPak A technological advancement
in differential pressure flow metering.
Designed from the innovative velocity profiling technology of the
FTI Translineal Flow Plate and the field proven performance of the
HHR Flow Tube, the HHR FlowPak consistently outperforms other flow measurement
technologies in the most demanding flow environments. |
|
Highest Accuracy
Energy Efficient
Installation Versatility
No Upstream and Downstream Piping Requirements
Broad Range of Applications
|
   |
| HIGHEST
ACCURACY / PROVEN PERFORMANCE The HHR FlowPak delivers
proven performance based on extensive laboratory and field testing.
|
|
Empirical
data from Alden Research Laboratory show the coefficient of discharge
of the HHR FlowPak to be constant, independent of Reynolds Number,
and within + 0.5% of the predicted value, even when installed
directly after two elbows out of plane. This eliminates the need for
calibration testing to characterize the coefficient and accuracy of
each individual meter. When a higher degree of accuracy is desired,
the HHR FlowPak can be calibrated at a laboratory whose data is
NIST certifiable to an accuracy of + 0.25%. Documentation is available.
|
 |
|
|
|
|
|
|
|
Typ.
Requires Calibration to Determine
|
|
|
|
|
|
|
|
Varies
w/Beta and DP Typ. 25 - 75%
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Flanged,
Weld-in, Wafer, Saddle
|
*
Limited only by lower boundary of Reynolds Number
|
|
 |
Fluidic Techniques meets the requirements of the International Organization for Standardization and is ISO 9001 / 2008 Certified. |
|
|
| ENERGY
EFFICIENCY The HHR FlowPak provides
superior energy efficiency. |
|
Low
permanent pressure loss (PPL) equates to energy efficiency and reduced
operating cost. The HHR FlowPak has a lower permanent pressure loss than the orifice
plate, Annular Orifice, flow nozzle or wedge meter. In an orifice
plate the flow impacts with an abrupt surface and typically results
in a PPL of 2 psig. The HHR FlowPak has a smooth, contoured, obstruction free entrance
with a pressure recovery cone for enhanced pressure recovery. In many
cases the recurring operating cost savings offered by the HHR FlowPak in such applications
as high pressure, high temperature steam can actually pay for itself
in a very short period of time. |
 |
 |
ENERGY
EFFICIENT

COST EFFECTIVE
|
| |
|
|
| |
|
|
|
| INSTALLATION
VERSATILITY The HHR FlowPak provides
installation versatility in challenging situations. |
|
The
unique design ensures that a flow velocity profile is well developed
and properly defined prior to measurement. Fluidic Techniques has
conducted extensive performance testing on the HHR FlowPak at Alden Research
Laboratory utilizing two close coupled 90 degree elbows out of plane
immediately before and after the meter. Test results show high
accuracy and performance with NO ADDITIONAL UPSTREAM AND
DOWNSTREAM PIPING, even in disturbed flow applications. This key
feature assures installation versatility in tight piping systems whether
new construction or retrofit. This can result in significant cost
savings in larger, more expensive line sizes. |
| |
INSTALLATION
VERSATILITY

NO UPSTREAM PIPING REQUIREMENTS |
 |
|
The
HHR FlowPak adapts to the tightest piping systems without
compromising performance. When governing codes increase upstream
piping requirements, Fluidic Techniques designed the solution.
|
|
|
| RANGE
OF APPLICATIONS The HHR FlowPak is virtually unlimited in scope. |
|
There
are essentially no limitations to flow measuring applications for
the HHR FlowPak. They can
be used in natural gas, most chemicals, gasoline, oil, hydrogen, oxygen,
LNG, etc... The HHR FlowPak meets
the toughest flow measurement challenges such as high temperature,
high pressure main stream, and high pressure boiler feedwater, petrochemical,
power plants and offshore platforms. |
|
| FLEXIBLE
DESIGN |
| |
|
HHR-F
FlowPak
|
HHR-W
FlowPak
|
|
|
|
|
|
|
|
|
 ®
|
| |
Fluidic Techniques
Division of FTI Industries, Inc..
1213 Antlers Drive, Mansfield, TX 76063 USA
Tel: (817)473-4481 Fax: (817)473-6318
|
| |
|